Three Phase Load Flow Investigations in the Context of Smart Grid
Abstract
The developments & progress in communications, information and control have revolutionized the conventional grid. Currently integration of renewable energy resources, dynamic optimization techniques, advanced performance analysis tools, monitoring and measurements are handled under the smart grid umbrella. Central and distributed generation control requires efficient load flow analysis and monitoring at both levels. Three phase load flow investigations have been carried out on three real time systems: National Transmission and Dispatch Company (NTDC), 32-Bus 500/220 kV primary Power System, the distribution systems of Islamabad Electric Supply Company (IESCO) 11 kV, 81-nodes and University of Engineering & Technology (UET), Taxila 21-nodes by simulating in MATLAB Simulink Environment. Smart Environment has been created in three systems with increasing complexity from system 1 to system 3 and system 3 is proposed Smart Grid Model for UET Taxila. NTDC primary network has been analyzed with the integration of Renewable Energy Resources (RERs), Static Var Compensators (SVC) and IESCO distribution network subject to RERs, Distribution Static Compensation (D-STATCOM) with monitoring of parameters at control Centre in both cases. System 3 is simulated with Solar Integration, D-STATCOM, Electric Fuel Cell Vehicle (FCV), Intelligent Distribution Boards (DBs), and monitoring through Transmission Communication Protocol over Internet Protocol (TCP/IP) in control Centre. Idea of smart DBs is proposed and implemented for load management. The simulation results of three-phase Load Flow Analysis successfully proved its potential strength for smart environment.References
B. Stott and O. Alsaç, IEEE Transactions on Power Apparatus and
Systems PAS-93 (1974) 859-869.
W. F. Tinney and C. E. Hart, IEEE Transactions on Power Apparatus
and Systems PAS-86 (1967) 1449-1460.
R. Broadwater, A. Chandrasekaran, C. Huddleston, and A. Khan,
Electric Power Systems Research 14 (1988) 23-33.
A. Hanif and M. A. Choudhry, The Nucleus 50, No. 2 (2013)
-3.
C. S. Cheng and D. Shirmohammadi, IEEE Transactions on Power
Systems 10 (1995) 671-679.
K. Lo and C. Zhang, Decomposed Three-Phase Power Flow Solution
Using the Sequence Component Frame, IEEE Proceedings in
Generation Transmission and Distribution C (1993) pp. 181-188.
X.-P. Zhang, W.-J. Chu, and H. Chen, Decoupled Asymmetrical
Three-phase Load Flow Study by Parallel Processing, IEEE
Proceedings in Generation, Transmission and Distribution 143
(1996) pp. 3-5.
S. Ashfaq, A. Arif, A. Shakeel and T. Mahmood, The Nucleus 51,
No 2 (2014) 259-274.
M. Abdel-Akher, K. M. Nor and A.A. Rashid, IEEE Transactions on
Power Systems 20 (2005) 1389-1397.
J. Ainsworth, Harmonic Instability Between Controlled Static
Convertors and AC Networks, Electrical Engineers Proceedings of
the Institution of Electrical Engineers 114 (1967) 949-957.
S. Bruno, S. Lamonaca, G. Rotondo, U. Stecchi, and M. La Scala,
IEEE Transactions on Industrial Electronics 58 (2011) 4504-4513.
L.A. Gallego, E. Carreno, and A. Padilha-Feltrin, Distributed
Generation Modelling for Unbalanced Three-phase Power Flow
Calculations in Smart Grids, in Transmission and Distribution
Conference and Exposition, Latin America (2010), IEEE/PES (2010)
pp. 323-328.
Annual Report, Public Relations Division, WAPDA, Lahore (2004).
T.N. Malik and M. Amin, Load Flow Test Circuit for WAPDA
Primary Grid System, 1st National Multi topic Conference, College
of EME;, National University of Science and Technology,
Rawalpindi, November 28-29 (1995), pp.3-5.